Get a quoteWhatsApp
LANTUVIA HFP 12.3 kW Hybrid Solar Inverter
Product appearance illustration

HFP123248 · LANTUVIA

HFP 12.3 kWHybrid Solar Inverter

12.3kW single-phase output with two independent MPPT inputs, 6,000W PV input per channel and 180A maximum charging. Compare for projects with two separate PV arrays.

Rated output power
12.3 kW
MPPT inputs
2
Max. total charging current
180 A

Contact us for pricing

48V battery system

Pure sine wave output

10ms typical transfer

RS485 · WiFi / app optional

Technical specifications

Specifications follow the supplied HFP manual. The 12.3kW designation is corrected as confirmed by LANTUVIA; AC current values are flagged where awaiting confirmation.

Solar input
HFP123248 · Solar input
Max. PV input power6,000 W × 2
MPPT voltage range80–450 VDC
Rated PV input voltage280 VDC
Max. PV open-circuit voltage (Voc)500 VDC
Max. PV input current22 A × 2
MPPT inputs2
Battery & charging
HFP123248 · Battery & charging
Battery typeFlooded lead-acid / lithium / user-defined settings
Rated battery voltage48 VDC
Battery voltage range42–60 VDC · default
Max. PV charging current180 A
Max. utility charging current120 A
Max. total charging current180 A
Grid-connected AC output
HFP123248 · Grid-connected AC output
Rated output power12.3 kW
Rated AC output voltage220 / 230 / 240 VAC
Grid voltage range187–264 VAC
Rated AC output frequency50 / 60 Hz
Grid frequency range47–52 Hz (50 Hz) / 57–62 Hz (60 Hz)
Rated AC output current46.7 / 44.9 / 42.9 AAt 220 / 230 / 240V respectivelyManual value · pending confirmation
Power factor>0.98 · at rated power

The 12.3kW manual lists 46.7 / 44.9 / 42.9A at 220 / 230 / 240V. These current values remain pending confirmation and should not be used to size AC wiring or protection.

Off-grid operation · AC input & output
HFP123248 · Off-grid operation · AC input & output
Rated AC input voltage220 / 230 / 240 VAC
Utility input voltage range165–280 VAC / 120–280 VAC · configurable
Rated AC input frequency50 / 60 Hz
Utility input frequency range45–55 Hz (50 Hz) / 55–65 Hz (60 Hz)
Rated output power12.3 kW
Rated AC output voltage220 / 230 / 240 VAC
Output voltage accuracy±2%
Rated AC output frequency50 / 60 Hz
Output frequency accuracy±1%
Output waveformPure sine wave
Utility bypass · AC input & output
HFP123248 · Utility bypass · AC input & output
Rated AC input voltage220 / 230 / 240 VAC
Grid voltage range187–264 VAC
Rated AC input frequency50 / 60 Hz
Grid frequency range47–52 Hz (50 Hz) / 57–62 Hz (60 Hz)
Rated output power12.3 kW
Rated AC output voltage220 / 230 / 240 VAC
Rated AC output current46.7 / 44.9 / 42.9 AAt 220 / 230 / 240V respectivelyManual value · pending confirmation

The 12.3kW manual lists 46.7 / 44.9 / 42.9A at 220 / 230 / 240V. These current values remain pending confirmation and should not be used to size AC wiring or protection.

System specifications
HFP123248 · System specifications
Max. battery-to-AC efficiency94% · peak
MPPT tracking efficiency≥99.9%
Transfer time10 ms · typical
DisplayLCD + LED
CoolingIntelligent fan control
CommunicationRS485 / WiFi app monitoring (optional)
Protection ratingIP20
MountingWall-mounted
Protection
HFP123248 · Protection
Battery undervoltage alarm44 VDC · default
Battery undervoltage protection42 VDC · default
Anti-islanding protection≤2 s
Overload protectionAutomatic protection (battery mode); breaker or fuse (utility mode)
Output short-circuit protectionAutomatic protection (battery mode); breaker or fuse (utility mode)
Overtemperature protection>90°C · inverter and charging shut down
Environment
HFP123248 · Environment
Operating temperature−10–50°C
Storage temperature−15–60°C
Noise≤55 dB
Altitude2,000 m · derating required above
Relative humidity0–95% · non-condensing
Dimensions & weight
HFP123248 · Dimensions & weight
Product dimensions (parameter table)535 × 462 × 117 mm
Installation outline (H × W × D)560 × 462 × 123 mm
Mounting hole spacing360 mm
Package dimensions630 × 557 × 212 mm
Net weight14.7 kg
Gross weight16.7 kg

Product dimensions follow the parameter table; installation outline includes the dimensions shown on the mounting drawing. Confirm the final installation drawing before fitting.

LANTUVIA · 51.2V LiFePO₄

Battery + inverter, selected together.

Discuss an HFP inverter with one of our five 51.2V LiFePO₄ batteries. Confirm the exact model, BMS communication, charging settings and system output for your project.

Battery capacity (kWh) and inverter output (kW) describe different things. Our battery data lists 195A continuous discharge, equivalent to 9.984kW DC at 51.2V before conversion losses.

A 12.3kW inverter rating does not establish 12.3kW AC output from a single battery. Ask us to confirm the complete battery, solar and utility configuration for your load.

LANTUVIA · Installer & distributor inquiries

Discuss your project

Tell us the product, quantity and destination. We will use these details to respond to your inquiry.

Company, inverter & contact details (optional)

Only provide contact details you want us to use for this inquiry.