Home battery sizing

Check daytime solar supply first, then size the battery for nighttime and remaining use. You can also select full-day outage backup.

Free · no registration

See the full results without leaving your contact details. Inputs stay in this browser tab; solar coordinates are sent to PVGIS for the estimate.

01 Solar & inverter

No valid solar result yet. Full-day backup is used for now; calculate solar first to deduct direct daytime supply.

Edit solar estimate →
Estimated daily energy—Selected model: —
View selection results ↓

Appliance counts

Lights, router & charging

Calculation assumptions

Lights: area×3W×40% simultaneous use×5h; router 10W×24h; charging 0.03kWh/person/day. Fridge 1.2kWh/unit/day; TV 80W×4h/unit; AC average 800W×6h/unit. If a washer is present: one cycle/person/week at 0.5kWh/cycle, not multiplied by machine count. If an electric water heater is present: 1.5kWh/person/day, not multiplied by unit count. A ±30% scenario range is illustrative, not a confidence interval. Measured daily energy overrides estimates. Delivered battery energy assumes nominal×90% discharge×90% efficiency; standby is not separately modelled.

View selection results ↓

Estimated daily energy

— kWh

Scenario range for different usage habits

Illustrative energy estimate, not measurements, a global average or a runtime guarantee. It does not confirm simultaneous appliance operation.

Inverter matching

Counts provide only an initial assessment. Confirm simultaneous loads, starting current, battery/BMS output, local voltage and phase before selecting an inverter.

Solar & recharging

Grid charging may suit backup use. To reduce grid purchases or run off-grid, assess solar or another charging source. Sizing requires location, sunlight and installation details.

Continuous-load runtime is supplementary; use daily energy for household planning.

16.1 kWh: 13.0 hours

30.1 kWh: 24.3 hours

32.2 kWh: 26.0 hours

These are assumed average loads, not measured performance. AC consumption varies; washing excludes heating and drying. Actual runtime depends on temperature, reserve and losses. Simultaneous operation requires confirmation of battery/BMS output, inverter rating and starting current.